Product

Fire Rated Swing Glass Door

Fire rated insulated glass doors tested to the latest SCDF requirement - EN 1634-1:2014, with impact test to BS 6206:1981. Door types: single leaf, equal leaf and unequal leaf swing doors.

  • Tested in BS EN 16341
  • Tested in UL 10C
  • EI 60 & EI 120 Swing Door (Floor Spring System)
Fire Rated Swing Glass Door

Installed by Vanson

6 photographs from real installations and fire tests

Fire rated swing glass door installation
Fire rated swing glass door installation

BCA Code on Accessibility in the Built Environment 2013, Chapter 4.4.2: "The minimum clear opening of doorways shall be 850mm measured between the face of the door and the face of the doorstop with the door open at 90°, as illustrated in Figure 22."

Fire Rated Glass Door System (Insulated)

  • Tested in BS EN 16341
  • Tested in UL 10C
  • EI 60 & EI 120 Swing Door (Floor Spring System)
  • EI 60 & EI 120 Swing Door (Hinge System)
  • EI 60 & EI 120 Swing Door (Auto Swing Operator System)
  • EI 60 & EI 120 Sliding Door (Auto Sliding Operator System)

60 minutes integrity and 60 minutes insulation

LFG EI 60

  • Thickness - +/- 29mm
  • Weight - 47 kg/m²
  • Direct airborne sound reduction (EN12758) Rw(C,Ctr) - 44 dB
  • Shading coefficient - 0,82
  • Light transmittance - 78,4
  • U-value (EN673) - 4,44 W/m²K
  • Mechanical resistance against sudden temperature changes - 200°

Contraflam 60-3

  • Thickness - +/- 27mm
  • Weight - 59 kg/m²
  • Sound reduction Rw (EN140-3) - 43 dB
  • Shading coefficient - 0,65
  • Light transmittance - 81%
  • U-value (EN673) - 4,44 W/m²K

120 minutes integrity and 120 minutes insulation

LFG EI 120

  • Thickness - +/- 52mm
  • Weight - 75 kg/m²
  • Direct airborne sound reduction (EN12758) Rw(C,Ctr) - 46 dB
  • U-value (EN673) - 3,77 W/m²K
  • Mechanical resistance against sudden temperature changes - 200° K

Ask about this door