Fire Rated Swing Glass Door
Fire Rated Insulated Glass Door – Tested as per in accordance with the latest SCDF Requirement – EN 1634-1:2014 with Impact Test in BS 6206:1981 Door Type : Single leaf swing door, Equal leaf swing door, Unequal leaf swing door ** BCA Code on Accessibility in the Built Environment 2013 – “Chapter 4.4.2 The minimum clear opening of doorways shall be 850mm measured between the face of the door and the face of the doorstop with the door open at 90° as illustrated in Figure 22”.
60 Minutes Integrity and 60 Minutes Insulation
- 1. LFG EI 60
- Thickness – +/- 29mm
- Weight – 47 kg/m²
- Direct airborne sound reduction (EN12758)Rw(C,Ctr) – 44 dB
- Shading coefficient – 0,82
- Light transmittance – 78,4
- U-value (EN673) – 4,44 W/m²K
- Mechanical resistance against sudden temperature changes – 200°
2. Contraflam 60-3
- Thickness – +/- 27mm
- Weight – 59 kg/m²
- Sound reduction Rw (EN140-3) – 43 dB
- Shading coefficient – 0,65
- Light transmittance – 81%
- U-value (EN673) – 4,44W/m²K
120 minutes Integrity and 120 minutes Insulation
- LFG El 120
- Thickness – +/- 52mm
- Weight – 75 kg/m²
- Direct airborne sound reduction (EN12758)Rw(C,Ctr) – 46 dB
- U-value (EN673) – 3,77 W/m²K
- Mechanical resistance against sudden temperature changes – 200° K